Home › Specialized Modular Buildings › Blast-Resistant Modules
Specialized Modular Buildings

Blast-Resistant Modules

Protected buildings for industrial operations.

Mobile or stationary modular buildings combine a high-strength steel structure with fire-rated walls, doors and windows. Gas detection, an airlock and pressurization can be integrated to suit the occupied-building requirements.

Discuss Your Module →
Blast-Resistant Modules
Integrated Systems

Product configuration

Structural Envelope

Blast load criteria guide the primary steel, enclosure, doors and window design. Single and multiple module arrangements support different room layouts.

Safety Integration

Gas detection with alarms, pressurization and an airlock coordinate with the operating panel and building services.

Configurable Building Duty

Operating rooms, equipment rooms and other occupied spaces can be configured with project-specific equipment and utility interfaces.

Product Specifications

Design parameters

ItemConfiguration
Blast rating3 bar, subject to the specified load profile and project verification
Fire integrity4 hours
Fire resistance & thermal insulation2 hours
ArrangementMobile or stationary, single or multiple modules
StructureHigh-strength steel with fire-rated enclosure components

Performance, dimensions and approvals are specified for the project design basis and selected module.

Module dimensions

ModelExterior L × W × H (mm)Arrangement
BRM-60306,000 × 3,000 × 3,000Single
BRM-20ST6,058 × 2,438 × 2,591Single
BRM-20HH6,058 × 2,438 × 2,896Single
BRM-40ST12,192 × 2,438 × 2,591Single
BRM-25103525,000 × 10,000 × 3,500Multiple
BRM-20104020,000 × 10,000 × 4,000Multiple
Configuration & Approvals

Defined for your operating requirements.

Options & Interfaces

Fresh-air chemical filtration, outdoor air intake treatment, emergency breathing air, positive pressure shielding and interlocked HVAC / fire and gas systems.

Design Basis

Occupied-building design follows the applicable API RP 752 / 753 requirements. Site-specific siting assessment, blast pressure and duration, fire exposure and occupancy determine the final design.

MDOW Project Coordination

MDOW coordinates technical clarification, equipment interfaces, modular supply scope and delivery with the specialist manufacturing resources.

Product Views

From layout to integrated module.

Define your module requirements.

Share the site conditions, operating duty, layout and required interfaces with MDOW.